CONVERTOR with EVAPORATIVE COOLER
S-H Industrial rated “ConvertoR” and Combination Coolers are packaged systems
specifically designed for producing industrial or agricultural grade ammonium
hydroxide (NH4OH). Each unit has: A Spencer-Harris Chemical Plants Division
patented Instantaneous Reaction Jet (ASME Code), process water/recycle booster
pump, forged steel fittings and schedule 80 ammonia piping, 150# fittings and
schedule 40 water and recycle piping, both the ammonia and water/recycle lines
have check valves and multi turn throttling valves, most units are provided
with water and ammonia flow indicator for field installation externally, S-H
Safety view tester with unique “Non-Spin” hydrometer reading in percent
ammonia, sample/scrubber return pumping system, panel mounted back pressure
gauge, panel mounted process water and ammonia pressure gauges, Reaction
Temperature Gauge with high and low pre-sets which activate a 100 db alarm. The
coolers are forced air, counter flow design and an integral part of the unit.
The coolers consist of one or more tube axial fans,
drift eliminator section, spray system, plate coils, water catch basin and one
or more cooler pumps. All units are built for 3/60/230 V.A.C. service with
other voltages optionally available. A circuit breaker and motor starting relay
with overloads are provided for each motor. All the electrical components are
housed in a N.E.M.A. 4 stainless steel enclosure with
N.E.M.A. 4 push buttons and pilot lights. Each ConvertoR
is wired with a splitter block for the customers’ high voltage connection. A
terminal point for 1/60/120 V.A.C. is also provided for incoming control
power. All motors are T.E.F.C.
Every unit is a
quality package designed with the customer in mind. All components and
materials are selected for long trouble free service and mounted on or housed
in an all steel cabinet with large access doors and removable panels. The units
are easily placed on a concrete slab by lift rings provided on all four
corners. Butt and 100% welds are used extensively in areas that would otherwise
result in an unpainted metal surface. Critical areas receive a tarmastic coat prior to a final all weather coating. ALL
S-H Chemical Plants Division equipment is backed by virtually 100% inventory of
parts for immediate emergency service.
|
VARIETY OF MODELS |
|||
|
MODEL |
*NOMINAL RATING T.P.H. |
APPROXIMATE SLAB SIZE |
APPROXIMATE WEIGHT |
|
B1015C |
10-15 |
7’ x 12’ |
4,800# |
|
B2025C |
20-25 |
7’ x 12’ |
6,800# |
|
B30400 |
30-40 |
7’ x 18’ |
9,200# |
|
B40500 |
40-50 |
7’ x 18’ |
10,500# |
SPECIAL CONSTRUCTION MATERIAL OR CAPACITIES
AVAILABLE
* RATING BASED ON TONS PER HOUR OF PRODUCT
AND A CONCENTRATION OF 24.11% AMMONIA.